最近一直在折腾DMC 监控 Dell 服务器,  Altiris 6 对Dell的监控策略会丰富很多 ,到了 7 严重缩水,
6的策略又不能转化成7 ~~比较郁闷~~ 唯有自己去写
不过最算给我写完了大部分常用的~~ 主要是 电源、电压、风扇、温度、处理器、内存、电池 等等 ~~列表如下:
Dell Global System Status
Dell Chassis Status
Dell Power Supply Status Combined
Dell Voltage Status Combined
Dell Amperage Status Combined
Dell Cooling Device Status Combined
Dell Temperature Status Combined
Dell Memory Device Status Combined
Dell Chassis Intrusion Status Combined
Dell Power Unit Status Combined
Dell Cooling Unit Status Combined
Dell Processor Device Status Combined
Dell Chassis Model Name
Dell Chassis Asset Tag Name
Dell Chassis Service Tag Name
Dell Power Unit Status
Dell Power Supply Status
Dell Power Supply Input Voltage
Dell Voltage Probe Reading [1/1000 V]
Dell Voltage Probe Upper Critical Threshold [1/1000 V]
Dell Voltage Probe Lower Critical Threshold [1/1000 V]
Dell Amperage Probe Upper Critical Threshold
Dell Amperage Probe Lower Critical Threshold
Dell Amperage Probe Reading
Dell Battery Status
Dell Battery Reading
Dell Cooling Unit Status
Dell Cooling Device Status
Dell Cooling Device Reading
Dell Cooling Device Upper Critical Threshold
Dell Cooling Device Lower Critical Threshold
Dell Temperature Probe Status
Dell Temperature Probe Reading [1/10 degrees C]
Dell Temperature Probe Upper Critical Threshold [1/10 degrees C]
Dell Temperature Probe Upper Warning Threshold [1/10 degrees C]
Dell Temperature Probe Lower Warning Threshold [1/10 degrees C]
Dell Temperature Probe Lower Critical Threshold [1/10 degrees C]
Dell Network Device Status
Dell Network Device Connection Status
Dell Network Device TOE Enabled
Dell Network Device RDMA Enabled
Dell Network Device SCSI Enabled
Dell Field Replaceable Unit Information Status
Storage Management Global System Status
Storage Management Agent Smart Thermal Shutdown
Storage Management Controller Rollup Status
Storage Management Channel Rollup Status
Storage Management Enclosure Rollup Status
Storage Management Array Disk State
Storage Management Array Disk Rollup Status
Storage Management Array Disk Smart Alert Indication
Storage Management Fan Speed Lower Critical Threshold
Storage Management Fan Speed Upper Critical Threshold
Storage Management Fan Speed
Storage Management Fan Rollup Status
Storage Management Power Supply Rollup Status
Storage Management Temperature Lower Warning Threshold [1/10 degrees C]
Storage Management Temperature Lower Critical Threshold [1/10 degrees C]
Storage Management Temperature Upper Warning Threshold [1/10 degrees C]
Storage Management Temperature Upper Critical Threshold [1/10 degrees C]
Storage Management Temperature Current Value [1/10 degrees C]
Storage Management Temperature Rollup StatusStorage Management Enclosure Management Module Rollup Status
Storage Management Battery Rollup Status
Storage Management Battery Charge Count
Storage Management Battery Maximum Charge Count
Storage Management Battery Predicted Capacity
Storage Management Virtual Disk State
Storage Management Virtual Disk Rollup Status
Dell System State Event Log Status
该回到正题,    到底怎么样做了~~我接下来简单说说
去symantec 网站 或者 DELL 网站 下载   Altiris 安装组件 (dell 网站 叫 DMC)  ,如果你之前没玩过 Altiris ,建议你直接去dell 的 DMC , 一个ISO 所有需要
的文件都有了。
安装过程,DMC 的ISO 中也有 视频介绍,全中文,应该没有多大问题 ,
然后在需要监控的DELL服务器安装 omsa 程序 ,当然你也可以通过 Altiris来推送 安装 ,另外安装 SNMP 协议,配置 只读 密匙 ,(如果需要使用 SNMP trap ,还需要配置 陷阱目标 ,就是监控服务器的地址)当然这些都可以通过Altiris 远程来实现
p_w_picpath
不过前提你需安装 Altiris Agent
然后,最关键的一步,在Altiris (DMC) 控制台上进行 一次 网络搜索, 记得 更改默认搜索的凭证 (SNMP ) ,
p_w_picpath
这样搜索完成之后 ,网络中的DELL服务器 就自动发现 ,自动开始监控了~
p_w_picpath
DMC 2.0 默认只有 简单的DELL 服务器状态 以及 电源方便的健康 ,需要其他类型的监控 ,还需要自己创建。
p_w_picpath
拔掉一个电源,然后再插上的过程
Altiris警报界面
警报详细
另外,你也可以查看相关设备的状态信息
p_w_picpath
最后介绍一个 排错工具 troubleshoot ,安装时也会自动安装 , 可以帮你检查 协议正确 ,服务器接受正确 等等一些问题
p_w_picpath