OracleSPARC服务器基础
Oracle SPARC服务器基础
及管理
Agenda
1. 服务器运行环境标准
2. Oracle Sparc T5140维护与ILOM管理
3. Oracle Solaris 基础
4. 收集日志、故障分析、解决和案例分享
2
SPARC T5140
环境
输入电压 100 - 240 VAC, 50-60Hz
8.3 - 7.2 A @ 100-120 VAC (max)
输入电流
4.3 - 3.6 A @ 200-240 VAC (max)
输入功率 822 W (max)
热力输出 2,804 BTU/hr (max)
Operating: 5°C to 35°C (41°F to 95°F)
温度
Nonoperating: -40°C to 65°C (-40°F to 149°F)
Operating: 10% to 90% relative humidity noncondensing, 27°C (80.6°F) maximum wet bulb
温度
Nonoperating: 93% relative humidity noncondensing, 35°C (95°F) maximum wet bulb
Operating: up to 3000m (10000 ft.)
海拔高度
Nonoperating: up to 12000m (40000 ft.)
Operating: 0.15G (z-axis), 0.10G (x,y axes) 5-500Hz swept sine
Vibration
Nonoperating: 0.5G (z-axis), 0.25G (x,y axes) 5-500Hz swept sine
Operating: 3G, 11ms half-sine
Shock Nonoperating: 1-inch roll-off free fall, front-to-back rolling direction, 25mm threshold height at
0.75 m/s impact velocity
3
机房环境要求
《电子计算机机房设计规范》GB50174-2008
4
Where Do You Want to Go如何去做?
Application 1 Application 2 … Application n Cloud
典型问题;
• 如何更快和更高效采用Oracle的新技术?
• 如何实施,风险如何?
• 如何获得实际体验?
• …
5
Oracle Helps Deploy Oracle Technologies优化实施
People熟练人员 Process方法和流程