偶然发现Oracle对于pfile启动参数的检查并不严格。
比如修改参数文件如下:
[oracle@yans1 ~]$ vi initprimary.ora
primary.__db_cache_size=1644167168
primary.__java_pool_size=16777216
primary.__large_pool_size=16777216
.
.
.
*.sga_target=2147483648
*.standby_file_management='AUTO'
*.undo_tablespace='UNDOTBS1
*.undo_management='AUTO'
*.user_dump_dest='/opt/ora10g/admin/primary/udump'
注意,在undo_tablespace参数的值UNDOTBS1后面缺少了一个引号,如果利用这个PFILE来创建SPFILE,Oracle会检查出错误:
SQL> create spfile from pfile='/home/oracle/initprimary.ora';
create spfile from pfile='/home/oracle/initprimary.ora'
*
ERROR at line 1:
ORA-01078: failure in processing system parameters
LRM-00111: no closing quote for value 'AUTO'
'
但是如果尝试利用这个初始化参数启动到nomount或mount状态,Oracle并不会对参数的正确性进行检查:
SQL> startup mount pfile=initprimary.ora
ORACLE instance started.
Total System Global Area 2147483648 bytes
Fixed Size2074112 bytes
Variable Size486541824 bytes
Database Buffers1644167168 bytes
Redo Buffers14700544 bytes
Database mounted.
SQL> show parameter undo
NAMETYPEVALUE
------------------------------------ ----------- ------------------------------
undo_managementstringMANUAL
undo_retentioninteger900
undo_tablespacestringAUTO'
可以看到,UNDO_TABLESPACE的值变成了AUOT’,而UNDO_MANAGEMENT的值则丢失,变成了系统的默认值。
这种情况数据库还可以打开:
SQL> alter database open;
Database altered.
SQL> select name from v$datafile;
NAME
----------------------------------------------------------------------------------------
/data/oradata/primary/system01.dbf
/data/oradata/primary/undotbs01.dbf
/data/oradata/primary/sysaux01.dbf
/data/oradata/primary/users01.dbf
/data/oradata/primary/test01.dbf
/data/oradata/primary/new01.dbf
/data/oradata/primary/new02.dbf
7 rows selected.
当然只要是非SYS用户执行任何的需要回滚段的操作,都会导致错误:
SQL> conn test/test
Connected.
SQL> create table t_undo (id number) tablespace new;
create table t_undo (id number) tablespace new
*
ERROR at line 1:
ORA-01552: cannot use system rollback segment for non-system tablespace 'NEW'
看来Oracle对于启动参数的检查还存在漏洞。